Medical Waste Reduction System Performance Sheet - MD-1000

ASPECT
DATA

Process

  • 3-chamber, continuous batch (weighing, microwave reduction, cooling / grinding)

Cycle time

  • 60-80 minutes (varies depending on load)

Load capacity

  • 150 pounds/load (68 kg/load)

Processing Capacity

  • 2,700 pounds/day (1,230 kg/day), 485 tons/year (440 tonnes/year)

Output

  • Sterilized landfill-ready carbon residue
  • 80% mass/volume reduction

Energy Consumption

  • 120 kW peak load
  • 85 kW average

Energy Costs

  • $4.25/hour (based on $0.05 US per kWh)

Effectiveness

  • Complete sterilization
  • Level-4 pathogen inactivation
  • 6 log10 reduction of spores

Floor Space

  • Main unit 9.3 ft x 32.4 ft (2.83 m x 9.9 m)
  • Auxiliary equipment 200-300 ft2 (19-28 m2)
  • Not required as a single area

Height Requirements

  • 12 ft (3.7 m)

Staffing

  • Current household or environment staff (10 minutes/hr during operation)

Emissions

  • Water
  • Scrubber discharge to sanitary sewer
  • Air fed to microturbine or low volume thermal oxidizer (120 cfm peak)


EWI is currently proceeding with the design of larger continuous throughput models. Custom designs and applications can be prepared and delivered based on customer specifications.